CCTHL - 4183 HIGH SOLIDS SANDING SEALER, S7146-00

  • MSDS: CCTHL
  • Manufacturer: GEMINI COATINGS INC
  • Product Name: 4183 HIGH SOLIDS SANDING SEALER, S7146-00
  • National Stock Number: 8010-00N074941
Product Identification

Product ID:4183 HIGH SOLIDS SANDING SEALER, S7146-00
MSDS Date:04/21/1994
FSC:8010
NIIN:00N074941
MSDS Number: CCTHL

Responsible Party
GEMINI COATINGS INC
2300 HOLLOWAY DR
EL RENO, OK 73036
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 405-262-5710

Preparer: JUDY

Cage: GEMIN

Contractor
GEMINI COATINGS INC
UNKNOW EL RENO, OK 73036 US

Telephone: 405-262-5710

Cage: GEMXN

Ingredients

1.040

OSHA PEL N/K

ACGIH TLV: N/K


1.4%

CAS: 108-88-3

RTECS: XS5250000

OSHA PEL 200 PPM; Z-2

ACGIH TLV: S, 50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


32 @ 68F.

CAS: 67-63-0

RTECS: NT8050000

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM/500 STEL


2-BUTANONE; (METHYL ETHYL KETONE) (MEK) (SARA 313)

CAS: 78-93-3

RTECS: EL6475000

OSHA PEL 200 PPM

ACGIH TLV: 200 PPM/300 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ACETIC ACID, ISOBUTYL ESTER; (ISOBUTYL ACETATE) (CERCLA).

CAS: 110-19-0

RTECS: AI4025000

OSHA PEL 150 PPM

ACGIH TLV: 150 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


RESIN; (RESIN 25)

OSHA PEL N/K

ACGIH TLV: N/K


ZINC STEARATE

CAS: 557-05-1

RTECS: ZH5200000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: N/K


5.579 LBS/GAL, 668.531

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K


DANGEROUS FIRE HAZARDS & MODERATE EXPLOSION HAZARDS

RTECS: 9999999ZZ


FUMES. KEEP OUT OF DRAINS, SEWER/WATERWAYS. IF

RTECS: 9999999ZZ


FIRE AUTHORITIES. NOTIFY LOCAL HEALTH AND POLLUTION

RTECS: 9999999ZZ


SKIN AREAS W/WATER. CNTNRS OF THIS MATL MAY BE

RTECS: 9999999ZZ


RESIDUE (VAP, LIQ, AND/OR SOLID), ALL HAZARD

RTECS: 9999999ZZ


NATURAL RUBBER, NEOPRENE, BUNA N OR NITRILE.

RTECS: 9999999ZZ


& FULL LENGTH FACESHIELD .

RTECS: 9999999ZZ


PROPERLY LAUNDERED.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TOLUENE APPEARS ON THE NAVY LISTING OF
OCCUP CHEM REPROD HAZARDS. SEEK CONSULTATION FROM APPROP HLTH
PROFESSIONALS CONCERNING LATEST HAZARD LIST INFO & SAFE HNDLG &
EXPOS INFO . TOXICOLOGY INFO: THIS PROD IS SEVERELY IRRITATING TO
EYES. EXPOS MAY CAUSE EXTENSIVE CORNEAL INJURY. WIDESPREAD CONTACT
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:W/SKIN FOR SEVERAL HRS CAN CAUSE
HARMFUL AMTS OF MATL TO BE ABSORBED. EXCESS INHAL OF VAPS CAN CAUSE
NASAL & RESP IRRIT, DIZZ, WEAK, FATG, NAUS, HDCH, POSS UNCON & EVEN
ASPHYX. HIGH VAP CONCS /PRLNGD BRTHG OF LOWER CONCS MAY RESULTIN
DAMAGE TO LIVER, KIDNEY, LUNGS & BLOOD FORMING ORGANS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE:FLUSH W/LUKE WARM WATER FOR @ LST 15 MINS. SEEK PHYS
IMMED. SKIN:REMOVE CONTAMD CLTHG, WASH AREA IMMED W/SOAP & WATER.
SEE PHYS IF IRRIT PERSISTS. INHAL:REMOVE EXPOS INDIVIDUAL TO FRESH
AIR & AID BRTHG IF NEC. CONT PHYS IMMED. INGEST:RINSE MOUTH IMMED.
DRINK 1-2 GLASSES OF WATER TO DILUTE. DO NOT INDUCE VOMIT. CONT
PHYS OR POISON CONTROL CENTER IMMED.

Fire Fighting

Flash Point Method:TCC
Flash Point:25.0F,-3.9C
Lower Limits:1.0%
Upper Limits:12.0%
Extinguishing Media:THE NATIONAL FIRE PROT ASSOC CLASS B EXTING IS
DESIGNED TO EXTINGUISH NFPA CLASS 1B FLAMMABLE LIQUID FIRES.
Fire Fighting Procedures:NIOSH APPRVD SCBA & FULL PROT EQUIP . CLEAR
FIRE AREA OF UNPROTECTED PERS. WATER STREAM CAN SCATTER FLAMES.
SPRAY OF WATER MAY BE USED TO COOL (SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPKS & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN
EXPOS TO EXTREME HEAT. DO NOT APPLY TO HOT (SUPDAT)

Accidental Release

Spill Release Procedures:STAY UPWIND & AWAY FROM SPILL/LEAK UNLESS
WEARING APPROP PROT EQUIP. STOP &/OR CONTAIN DISCHARGE IF IT MAY BE
DONE SAFELY. KEEP ALL SOURCES OF IGNIT AWAY. VENTILATE AREA OF
SPILL. USE NON-SPK TOOLS FO R CLEAN UP. COVER W/INERT MATL TO
REDUCE (ING 10)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP PROD CNTNRS COOL, DRY, & AWAY
FROM SOURCES OF IGNIT. USE & STORE THIS PROD W/ADEQ VENT. DO NOT
SMOKE IN STORAGE AREAS.
Other Precautions:BOND & GROUND METAL CNTNRS WHEN TRANSFERRING LIQ.
AVOID FREE FALL OF LIQ IN EXCESS OF FEW INCHES. PERS SHOULD AVOID
INHAL OF VAPS. PERSONAL CONT W/PROD SHOULD BE AVOIDED. SHOULD CONT
BE MADE, REMOVE S ATURATED CLTHG & FLUSH AFFECTED (ING 12)

Exposure Controls

Respiratory Protection:IF EXPOSURE EXCEEDS TLV, USE NIOSH-APPROVED
RESPIRATOR TO PREVENT OVEREXPOSURE.
Ventilation:USE LOCAL EXHAUST AS REQD TO CONTROL VAP CONCENTRATIONS.
AVOID PRLNGD/RPTD BRTHG OF VAPS.
Protective Gloves:RESISTANT GLOVES SUCH AS (ING 14)
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS (ING 15)
Other Protective Equipment:APRON. ANSI APPRVD EYE WASH & DELUGE SHOWER
.
Work Hygienic Practices:WASH HANDS THORO BEFORE EATING/USING RESTROOM.
REMOVE CONTAMD CLTHG IMMED & DO NOT WEAR AGAIN UNTIL IT HAS BEEN
(ING 16)
Supplemental Safety and Health
FIRE FIGHT PROC:CLSD CNTNRS TO PVNT PRESS BUILDUP & POSS
AUTOIGNIT/EXPLO WHEN EXPOS TO EXTREME HEAT. IF WATER IS USED, FOG
NOZZ ARE PREF. EXPLO HAZ:SURFS. NEVER USE WELDING/CUTTING TORCH
ON/NEAR CNTNR (EVEN EMPTY) BECAUSE PROD (EVEN RESIDUE) MAY IGNITE
EXPLOSIVELY. LIQ & VAP STATES OF THIS SUBSTANCE ARE (ING 9)

Chemical Properties

Boiling Pt:B.P. Text:>175F,>79C
Vapor Pres:83 @ 68F
Vapor Density:HVR/AIR
Spec Gravity:0.88
Evaporation Rate & Reference:FASTER THAN BUTYL ACETATE
Appearance and Odor:LIQUID.
Percent Volatiles by Volume:82.61

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG ALKALINES, STRONG MINERAL ACIDS.
Stability Condition to Avoid:HIGH HEAT, SPARKS, FLAMES.
Hazardous Decomposition Products:OXIDATION MAY PRODUCE CARBON AND
NITROGEN OXIDES.

Disposal

Waste Disposal Methods:DO NOT FLUSH TO SEWER, WATERSHED, OR WATERWAY.
DISPOSE OF PRODUCT IN ACCORDANCE WITH APPLICABLE LOCAL, COUNTY,
STATE, AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.